Rcom PRO 20 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Tierpflege Rcom PRO 20 herunter. Rcom PRO 20 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 1
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.R-com.co.kr
R
E
A
R
R
E
A
R
FR
O
N
T
Ver E 1.0.0
DIGITAL INCUBATOR
HUMI󰚟+
HUMI󰚟-
SET
󰚟
󰚟
󰚟
󰚟
󰚟
󰚟
A
U
T
O
M
A
T
I
C
󰚟
E
G
G
󰚟
T
U
R
N
I
N
G
󰚟
-
󰚟
T
E
M
P
E
R
A
T
U
R
E
H
U
M
I
D
I
T
Y
󰚟
C
O
N
T
R
O
L
CAL CAL
TEMPERATURE HUMIDITY
TURNING󰚟ON
HEATING
WATER󰚟EMPTY
HUMIDIFICATION
TEMP󰚟+
TEMP󰚟-
TURN
New
Digital Incubator
"OFF"
In case of low humidity
incubation
SETSET
SETSET
SETSET
SETSET
SETSET
SETSET
HUMI󰚟-HUMI󰚟-
HUMI󰚟-HUMI󰚟-
HUMI󰚟+HUMI󰚟+
TEMP󰚟-TEMP󰚟-
TEMP󰚟-TEMP󰚟-
TEMP󰚟+TEMP󰚟+
TEMP󰚟+TEMP󰚟+
℃↔℉
TURN
W
A
T
ER
W
A
T
ER
R
E
A
R
R
EA
R
FR
O
N
T
Universal Tray
1. Safety Cautions
Electrical hazards
Be careful the details below when you use.
Setting Cautions
Be careful the details below when you use.
Do not pull the cord when
taking out the power cord,
and keep wet hands away
from connecting plug.
Do not use a damaged
power cord or loose
outlet.
Risk of electric shock or fire.Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an
outlet.
Risk of fire or electrical overload.
Never pull the plug out of
the outlet during the
incubation period.
Incubation will be interrupted.
Do not twist or crush
electric cord.
Risk of electric shock or fire.
Cleaning Cautions
Be sure to disconnect the electric cord
from the outlet before cleaning.
Clean the incubator by a
soft cloth with a neutral
detergent.
Do not spray cleanser
directly on the incubator
surface.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
Brush away dust on the
plug with a dry cloth.
For special cleaning of
inner part per year, contact
to the service center.
Do not install under the
direct sunlight.
Do not install in dusty or
dirty environment.
Risk of fire or interference with
the incubation process.
Risk of damage or fire within
the incubator.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Do not install in moist or
humid environment.
Risk of interference with
the incubation process.
Risk of fire or electric shock.
Do not use any other
non-standard parts
except those provided.
Risk of damage or hatching
failure.
Please ensure that no
small objects get into
the holes on the incubator.
Risk of electric shock or fire.
Do not disassemble or
modify the incubator in
any way.
Risk if electric shock or fire.
If the incubator sounds
strange or emits smoke
contact your service
center.
Risk of electric shock or fire.
If the incubator requires
repair disconnect from the
power supply and please
contact to your service center.
Clean the incubator
thoroughly before storing.
Install away from heat
sources.
Risk of damage to the incubator
case and interference with
the incubation process.
Do not turn the incubator
upside down.
Water will pour out of the incubator,
and view window can be dropped
or damaged.
Ensure that the incubator is
installed on a stable surface
away from edges.
Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Do not cover the
ventilating opening.
Inner temperature can rise,
interrupting incubation.
Do not install where
children or other people
can touch with easy.
Risk of knocking the incubator
or accidental interference with
the controls.
View Window
For a clear view of
the incubation process.
( duplicated View Window )
Main Body-1 Main Body-2
Locking Button
See description of
the function and operation.
Digital Control Center
Vents for air circulation
For circulating warm air
For inlet of air
from outside
Air inlet vent
Power Connecting
For connecting
power cord.
To facilitate water top-up
for the humidity control.
Water Cap
Power Cord
User's Manual
View Window
Main Body-2
Main Body-1
Universal Tray
Egg turning Plate
4. How to Assemble
5. How to Replace Fuse
Lock the three locking
buttons at the front and rear
of the incubator.
Insert the power cord
in the socket at the back
of the main body.
View Window
Main Body-1
Main Body-2
3. Basic Components
2. Identification of Parts
Insert the electric cord in the connecting socket at the back of the Main body and
put the power cord into the outlet. The display will come on.
Open the watercap and fill the hole with clean water. And, refill water after 5 min.
The styrofoam ball floats on and blocks the hole when full.
(Humidity goes down temporarily, in case you refill water under incubation period.)
Place your eggs and cover the view window.
There can be some odor the first time you use the incubator, that is normal.There can be some odor the first time you use the incubator, that is normal.
Check the water level every three days and refill fully on incubation period.
The light for water top-up can remain for a while after you filled up.
Check the water level every three days and refill fully on incubation period.
The light for water top-up can remain for a while after you filled up.
The egg to incubate must be a fertilized egg. The egg to incubate must be a fertilized egg.
You should stop to fill in the water as soon as the Styrofoam ball floats on.
The ball will block the hole when full.
After filling up with water, never shake or turn over the main body of the incubator.
Be careful to close the view window completely; if not, the temperature will fail
to go up. (It will cause alarm.)
6. Before use
7. Operation Part
Temp. UP Button
Temp. Display
Temp. DOWN Button
(Lighting when working)
Heater Lamp
Humidity UP Button
Humidity DOWN Button
Setting Button
Humidity Display
(Lighting when working)
Humidification working lamp
(Blink with water shortage)
Water Supplement Lamp
How to OperateFunction
Explanation
Cels. / Fahr.
interchangable
How to change Cels. or Fahr.
Temp. Setting
Humidity Setting
How to turn off
Humidification Function
Setting of required temp.
Setting of
required
humidity.
Initialization
If you want to change setting value, keep pressing "SET" button and change the value.
Incubator Initialization
(Factory Setting)
REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.
Egg-Turning Setting Button
Turn on with automatic egg-turning mode.
(Blink when working)
Egg-Turning Lamp
Egg-Turning Setting /
Cancellation
UNDER 40%
Egg-Turning
Setting
Egg Tray
Adjust the space of dividers
according to egg size.
New Rcom 20 USER'S MANUALNew Rcom 20 USER'S MANUAL
8. Easy Function Operation
PX-20(Standard)
Digital Incubator
You can turn off humidification function when you don't fill water with your incubation
or when you need low humidity incubaion under 40%.
(Water supplement alarm will turn off with this function.
Refer to "How to turn OFF humidification function.")
Replace with new fuse.
( 250V 2.0A Ø5*20mm )
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
When the machine failed to
power on even if you pluged in,
remove the fixing piece like
the picture by screwdriver.
You can find assembled PCB
when open the cover.
Remove faulty fuse with screwdriver.
Seitenansicht 0
1

Inhaltsverzeichnis

Seite 1 - Cleaning Cautions

www.R-com.co.krREARREARFRONTVer E 1.0.0DIGITAL INCUBATORHUMI󰚟+HUMI󰚟-SET󰚟󰚟󰚟󰚟󰚟󰚟AUTOMATIC󰚟EGG󰚟TURNING󰚟-󰚟TEMPERATURE&HUMIDITY󰚟CONTROLCAL CALTEMPERATURE HU

Kommentare zu diesen Handbüchern

Keine Kommentare